If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Safety technique Emergency stop module BE 5982 safemaster * * * * * * * * 0221555 According to EU Directive for machines 98/37/EG According to EN 60 204-1, DIN VDE 0113 part 1 (11.98) Safety category 4 according to DIN EN 954-1 Output: 2 NO contacts for AC 250 V Single-channel emergency stop circuit LED indication for channels 1 / 2 and operating state Short circuit protection Wire connection: also 2 x 1,5 mm 2 stranded ferruled (isolated), DIN 46 228-4 or 2 x 2,5 mm 2 stranded ferruled DIN 46 228-1/-2/-3 * Width 22,5 mm www..com Function diagram Approvals and marking Pushbutton On Emergency stop (Off) ET Application * Protection of persons and machines * Emergency stop circuits on machines Indication K1 K2 M7218 LED power supply: LED K1/K2: on when operating voltage present on when output relays K1, K2 are energized Notes Block diagram A1(+) Y1 Y2 13 23 When using the E-stop module with "automatic start" mode, the automatic restart (according to EN 60 204-1 part 9.2.5.4.2 and 10.8.3) has to be inhibited by the machine control. Technical data PTC K1 K1 K1 Input Nominal voltage UN: Voltage range at 10 % residual ripple: at 48 % residual ripple: Nominal consumption: Control voltage Y1: Control current: Recovery time: Output DC 24 V DC 0,9 ... 1,1 UN DC 0,8 ... 1,1 UN approx. 1,6 W DC 24 V typ. DC 45 mA 0,5 s K2 K2 K2 Mains K1/K2 K1 K2 A2(-) M6760_a 14 24 Circuit diagram A1 13 23 24 A1 K1 K2 A2 Y2 14 24 M7384_a Y1 13 23 Contacts BE 5982.02: Response time: Release time: Contact type: Output rated voltage: Thermal current I th: Switching capacity to AC 15: 2 NO contacts max. 100 ms max. 35 ms Relay, positively driven AC 250 V see continuous limit curve (max. 6 A in one contact path) 5 A / AC 230 V for NO contact 2 A / AC 230 V for NC contact 105 switching cycles 600 switching cycles / h 4 A gL EN 60 947-5-1 10 x 106 switching cyles EN 60 947-5-1 EN 60 947-5-1 14 Y1 Y2 A2 Electrical life to AC 15 at 2 A, AC 230 V: Permissible switching frequency: Short ciruit strength max. fuse rating: Mechanical life: EN 60 947-5-1 All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. 1 BE 5982 / 30.10.01 d Technical data General data Operating mode: Temperature range: Clearance and creepage distances overvoltage category / contamination level: EMC Electrostatic discharge: HF irradiation: Fast transients: Surge voltages between wires for power supply: between wire and ground: Interference suppression: Degree of protection: Housing: www..com Vibration resistance: Climate resistance: Terminal designation: Wire connection: Continuous operation - 15 ... + 55 C Application examples 4 kV / 2 8 kV (air) 10 V / m 4 kV IEC 60 664-1 EN 61 000-4-2 EN 61 000-4-3 EN 61 000-4-4 Wire fixing: Mounting: Weight: Dimensions Width x height x depth: Standard type BE 5982.02 DC 24 V Article number: * Output: * Nominal voltage U N: * Width: Characteristics 1 kV EN 61 000-4-5 2 kV EN 61 000-4-5 Limit value class B EN 55 011 Housing: IP 40 EN 60 529 Terminals: IP 20 EN 60 529 Thermoplastic with V0 behaviour according to UL subject 94 Amplitude 0,35 mm frequency 10 ... 55 Hz, EN 60 068-2-6 15 / 055 / 04 EN 60 068-1 EN 50 005 1 x 4 mm2 solid or 1 x 2,5 mm2 stranded ferruled (isolated) or 2 x 1,5 mm2 stranded ferruled (isolated) DIN 46 228-1/-2/-3/-4 or 2 x 2,5 mm 2 stranded ferruled DIN 46 228-1/-2/-3 Plus-minus terminal scews M3.5, box terminal with wire protection DIN rail EN 50 022 170 g Single-channel emergency stop circuit, optionally with or without automatic On function. Set jumper Y1 - Y2 for automatic On function. The On button is omitted. 22,5 x 74 x 121 mm 0044292 2 NO contacts DC 24 V 22,5 mm stock item Contact reinforcement by external contactors. With switching currents > 5 A, the output contacts can be reinforced by external contactors with positively-driven contacts. The function of the external contactors is monitored by looping the NC contacts into the switch-on circuit (terminals Y1 - Y2). 250 200 150 100 50 0 Switching voltage U [V] 1 2 3 4 5 6 7 8 9 10 Switching current I [A] M 6732 Continuous current limit curve Limit curve for arc-free operation for a resistive load E. DOLD & SOHNE KG * D-78114 Furtwangen e-mail dold-relays@t-online.de * internet http://www.dold.com * Postf. 1251 * Tel. +49 7723 654 0 * Telefax +49 7723 654 356 2 |
Price & Availability of BE5982 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |